Compressors - Side channel

Side channel blowers are used to generate suction or blast air in heavy duty industrial applications. These turbo dynamic blowers are wear and maintenance free.

The rotating impeller pulls air in through the inlet side, accelerates the air or gas inside the housing, and then discharges it through the outlet side once it is fully pressurised. With single-stage blowers, the air rotates once inside the housing via both impeller sides before being suctioned off. This two-stage operation results in a higher volume flow. By means of an internal deflection of the air from the first to the second impeller side, in the case of two-stage blowers the air rotates twice inside the housing before it is suctioned off. This single-flow operation results in a higher vacuum or pressure.

NameCapacity
[m3/h]
Max pressure
[mbar]
Motor power
[kW]
Technical information
PDF
Send
inquiry
SV 1.50/341+ 1000,15 | 1~
0,18 | 3~
Inquiry
SV 5.90/175+ 950,37 | 1~
0,37 | 3~
Inquiry
SV 5.90/243+ 2200,37 | 1~
0,37 | 3~
Inquiry
SV 130/1130+ 75
+ 125
+ 210
+ 240
+ 280
0,55
0,75
1,1
1,25
1,5
Inquiry
SV 130/270+ 160
+ 250
+ 400
0,55
0,75
1,1
Inquiry
SV 200/1180+ 145
+ 225
1,1
1,5
Inquiry
SV 200/290+ 300
+ 410
1,1
1,5
Inquiry
SV 201/1190+ 135
+ 210
+ 340
1,1
1,5
2,2
Inquiry
SV 201/290+ 260
+ 420
1,1
1,5
Inquiry
SV 300/1325+ 165
+ 250
+ 340
2,2
3,0
4,0
Inquiry
SV 300/2160+ 330
+ 515
2,2
3,0
Inquiry
SV 400/1390+ 200
+ 290
+ 425
3,0
4,0
5,5
Inquiry
SV 400/2195+ 390
+ 530
3,0
4,0
Inquiry
SV 500/1510+ 190
+ 295
+ 435
4,0
5,5
7,5
Inquiry
SV 500/2260+ 370
+ 480
4,0
5,5
Inquiry
SV 700/1750+ 185
+ 285
+ 400
5,5
7,5
11,0
Inquiry
SV 700/2370+ 330
+ 500
5,5
7,5
Inquiry
SV 701/1750+ 185
+ 285
+ 400
5,5
7,5
11,0
Inquiry
SV 1100/11050+ 140
+ 260
+ 390
7,5
11,0
15,0
Inquiry
SV 1100/2520+ 260
+ 500
7,5
11,0
Inquiry
SV 1101/11050+ 140
+ 260
+ 390
7,5
11,0
15,0
Inquiry

Side channel blowers with a VARIAIR unit

VARIAIR
  • 0 - 100 Hz

    Use the frequency converter to change the motor speed according to the currect needs of the system.

  • Lower costs

    By using a frequency converter, you reduce energy costs as the device never works more than necessary.

  • Longer life span

    Because the device does not run at full power all the time, you extend its life.

  • System integration

    Connect the device to other system monitors.

VARIAIR_units
NameCapacity
[m3/h]
Max pressure
[mbar]
Frequency converter power
[kW]
Technical information
PDF
Send
inquiry
VARIAIR SV 130/1285+ 4054,0Inquiry
VARIAIR SV 130/2140+ 5504,0Inquiry
VARIAIR SV 201/1350+ 3404,0Inquiry
VARIAIR SV 201/2175+ 5604,0Inquiry
VARIAIR SV 300/1640+ 3557,5Inquiry
VARIAIR SV 300/2300+ 5707,5Inquiry
VARIAIR SV 300/1 | 87 Hz560+ 2554,0Inquiry
VARIAIR SV 400/1800+ 43011 - 22Inquiry
VARIAIR SV 500/11000+ 53011 - 22Inquiry
VARIAIR SV 700/11180+ 41011 - 22Inquiry
VASF 2.50/1-0.XXXXX48+ 290
+ 270
+ 280
0,65 @ 230 V
0,60 @ 115 V
0,77 @ 24 V DC
Inquiry
VASF 2.50/1-0.XXXXX BASIC48+ 195
+ 195
+ 180
0,40 @ 230 V
0,41 @ 115 V
0,40 @ 24 V DC
Inquiry
VASF 2.50/2-0.XXXXX24+ 560
+ 510
+ 550
0,65 @ 230 V
0,60 @ 115 V
0,75 @ 24 V DC
Inquiry
VASF 2.80/1-0.XXXXX90+ 280
+ 290
1,1 @ 230 V
1,1 @ 48 V DC
Inquiry
VASF 2.80/1-0.XXXXX BASIC90+ 190
+ 190
+ 170
0,65 @ 230 V
0,64 @ 115 V
0,70 @ 48 V DC
Inquiry
VASF 2.80/2-0.XXXXX45+ 570
+ 570
1,1 @ 230 V
1,1 @ 48 V DC
Inquiry
VASF 2.120/1-0.AC230143+ 2301,4 @ 230 VInquiry
VASF 2.120/1-0.ACXXX BASIC143+ 160
+ 160
0,85 @ 230 V
0,83 @ 115 V
Inquiry
VASF 2.120/2-0.AC23071+ 4601,4 @ 230 VInquiry

Gas-tight side channel blowers with a VARIAIR unit

(Gas tight)

NameCapacity
[m3/h]
Razmerje tlakov
p/p
Frequency converter power
[kW]
Technical information
PDF
Send
inquiry
VARIAIR SV 201/1 Gas-tight3701,34,0Inquiry
VARIAIR SV 300/1 Gas-tight6001,38+ 3557,5Inquiry
VARIAIR SV 300/2 Gas-tight2801,527,5Inquiry
VARIAIR SV 500/1 Gas-tight910
930
1,295
1,315
7,5
11 - 22
Inquiry
VASF 2.50/1-1.ACXXX Gas-tight471,29
1,27
0,65 @ 230 V
0,60 @ 115 V
Inquiry
VASF 2.50/2-1.ACXXX Gas-tight241,56
1,51
0,65 @ 230 V
0,60 @ 115 V
Inquiry
VASF 2.80/1-1.AC230 Gas-tight911,281,1Inquiry
VASF 2.80/2-1.AC230 Gas-tight451,571,1Inquiry
VASF 2.120/1-1.AC230 Gas-tight1431,231,4 @ 230 VInquiry
VASF 2.120/2-1.AC230 Gas-tight711,461,4 @ 230 VInquiry
en_GBEN